Q-Logic SANBOX2-8C Switch User Manual


 
B Command Line Interface
Set Config Command
59042-02 A B-27
switch
Initiates an editing session in which to change switch configuration settings. The
system displays each parameter one line at a time and prompts you for a value.
For each parameter, enter a new value or press the Enter key to accept the
current value shown in brackets.
Table B-8. Set Config Switch Parameters
Parameter Description
AdminState Switch administrative state: online, offline, or
diagnostics
BroadcastEnabled Enables (True) or disables (False) forwarding of
broadcast frames.
InbandEnabled Enables (True) or disables (False) the ability to
manage the switch over an ISL.
DefaultDomainID Default domain ID setting
DomainIDLock Prevents (True) or allows (False) dynamic
reassignment of the domain ID.
SymbolicName Descriptive name
R_T_TOV Receiver Transmitter Timeout Value. Specifies the
number of milliseconds a port is to wait to receive a
response from another port. The default is 100.
R_A_TOV Resource Allocation Timeout Value. The number of
milliseconds the switch waits to allow two ports to
allocate enough resources to establish a link. The
default is 10000.
E_D_TOV Error Detect Timeout Value. The number of
milliseconds a port is to wait for errors to clear. The
default is 2000.
FS_TOV Fabric Stability Timeout Value. The default is 5000
msec.
DS_TOV Distributed Services Timeout Value (Management
Server, Name Server). The default is 5000 msec.
PrincipalPriority The priority used in the FC-SW-2 principal switch
selection algorithm. 1 is high, 255 is low.
ConfigDescription The name for the configuration. The default is
undefined.