Chapter 8: Nodes, Node Groups, and Interfaces
147
Column
number
Tag or value
Details
12
Description
Optional.
To add a Power IQ Proxy power control interface to the CSV file:
See Power Control of Power IQ IT Devices (on page 337) for details
about configuring this interface type.
Column
number
Tag or value
Details
1
ADD
The first column for all tags is the
command ADD.
2
NODE-POWER-PIQ-INTERFA
CE
Enter the tag as shown.
Tags are not case sensitive.
3
Node Name
Required field.
4
Interface Name
Required field.
5
External Key
If the IT device has already been
added to Power IQ, find the
external key on the IT device's
page in the Data Center tab, and
enter the text in this field.
If the IT device has not been
added to Power IQ yet, enter a
text value, but make sure to use
the same value when adding the
IT device to Power IQ. You can
quickly make a file of all node and
interface information by exporting.
See Export Nodes (on page 149).
6
Managing Power IQ Name
Enter the name of the Power IQ that
manages the IT device. The name
must match the value in the Power IQ
Device Name field on the Access >
Power IQ Services > "Power IQ
Device Name" Configuration dialog.
See Configuring Power IQ Services
(on page 338).
7
Description
Optional.