![](http://pdfasset.owneriq.net/4/52/452c126b-5b41-4931-a299-3ead4940f659/452c126b-5b41-4931-a299-3ead4940f659-bg21.png)
( 33 / 74 )
3.4 A-D Conversion Bypass Capacitor
The emulation pod has foot patterns on the board for mounting a bypass capacitor. Mount a suitable
bypass capacitor as occasion demands.
Figure 3.2 shows where the bypass capacitors are mounted, whereas Figure 3.8 shows an enlargement
of the foot patterns.
Figure 3.8 Foot patterns of A-D conversion bypass capacitor
IMPORTANT
Note on the A-D Converter:
• Because a flexible board and other devices are used between the evaluation MCU
and the target system, the A-D converter operates differently from the actual MCU.
Make the final evaluation of the A-D converter from the actual MCU.