Renesas M30803T-RPD-E Network Card User Manual


 
( 43 / 74 )
(7) Connecting 144-pin 0.5-mm-pitch Foot Pattern
Figure 3.18 shows how to connect the emulation pod probe to the 144-pin 0.5-mm-pitch foot pattern
on the target system with the FLX-144NSD (not included), and here following is its procedure.
(1) Attach the NQPACK144SD (NQPACK, hereafter) included with the FLX-144NSD to the
target system.
(2) Attach the YQPACK144SD (YQPACK, hereafter) included with the FLX-144NSD to the
NQPACK, matching three holes of NQPACK and YQPACK.
(3) Insert the YQ-GUIDE's included with the YQPACK to the YQPACK, using the screwdriver
included with the NQPACK.
(4) Attach the FLX160-PRB to the FLX-144NSD.
(5) Attach the FLX-144NSD to the YQSOCKET144SDF.
Figure 3.18 Connecting emulation pod probe and 144-pin 0.5-mm-pitch foot pattern
CAUTION
Notes on Connecting the Target System:
Take care not to attach the converter board in a wrong direction. It may cause a fatal
damage to the emulation pod.
The small connectors of FLX-144NSD are guaranteed for only 50 insertion/removal
iterations.