RTS ADAM Network Card User Manual


 
5
Specifications
NOTE: The TBX–Tribus supports up to eight (8) frames in non-redundant mode. Slot 10 should be used if a third TBX–
Tribus card is needed.
Board Performance
Throughput Per Link:
360Mb/sec
SFP Fiber Transceivers:
Voltage:
3.3 V Rails
Standard Rate:
SONET OC12 or Gigabit Ethernet
Recommended Parts:
Multi-Mode:
Finisar - FTLF8519P2BNL (Oxide VCSEL, Maximum reach of 550m)
Single Mode:
Finisar - FTLF1422P1BTL (1310nm, Maximum reach 40km)
Fiber Cable Connector Type:
Multiple Mode Fiber LC–LC Duplex Connector – max length 500m (546.8 yd.)
Single Mode Fiber LC–LC Duplex Connector – max length 40km (24.9 miles)
Configuration Requirements
An MCII-e Master Controller card must be installed in the same frame as the TBX-Tribus. For more information, see
the MCII-e User Manual which can be found at www.rtsintercoms.com.
TABLE 1. Systems Supported by the TBX-Tribus Card
Links Used
# TBX Cards
per Frame
System Frames Supported Channels
1 1 AIO-8 2 256
1 1 AIO-16 2 512
3 1 AIO-8 3 384
3 1 AIO-16 3 768
6 1 AIO-8 4 512
6 1 AIO-16 4 880
10 2 AIO-8 5 640
10 2 AIO-16 5 880
15 2 AIO-8 6 768
15 2 AIO-16 6 880
21 2 AIO-8 7 880
21 2 AIO-16 7 880
28 3 AIO-8 8 880
28 3 AIO-16 8 880