Sanyo PLC-XK3010 Projector User Manual


 
56

This function returns all setting values except for the
, , ,
Lamp counter and Filter counter to the factory default
settings.

Warning log
This function records anomalous operations while the
projector is in operation and use it when diagnosing
faults. Up to 10 warning logs are displayed with the
latest warning message at the top of the list, followed
by previous warning messages in chronological order.

When the Factory default function is executed, all
the warning log records will be deleted.
This function is used to set a frequency for the filter
cleaning.


the submenu items.
Filter counter.........Show the total accumulated time
of the filter use timer setting.
..................... To set a timer, when the projector
reaches the time, the Filter warning
icon (Fig.1) appears on the screen
and the total accumulated time
turns red, indicating that the filter
replacement is necessary.
Filter counter reset... After replacing the filter, be sure
to reset the timer. The Filter warning icon will
not turn off until the filter counter is reset.
For details about resetting the timer, refer to
“Resetting the Filter Counter” on page 59.
Filter counter
Filter counter
Press the SELECT button to select , and
then use the Point buttons to set the timer.
Select from () depending
on the use environment.
Filter warning icon appears on the screen at a set time
(/2000H/3000H/4000H).
Fig.1 Filter warning icon

• This icon also appears at turning on.
The Filter warning icon (Fig.1) will not appear when
the Display function is set to  (p.46), during
(p.25), or  (p.26).
Setting