Chapter 4 Controlling the Monitor
Status
If some of the registered monitors are disabled by some
reasons (such as disconnecting the power source, dis-
connecting the LAN cable, disconnecting from the net-
work), control changes will continue to be effective for
the monitors that are still active. At the same time, the
deactivated monitors are excluded from the multi-con-
trol. The status of the registered monitors are indicated
under the monitor name. See the table below for status
indications.
If the multi-controlled monitor is in the standby mode, any change is not effective except timer
setting.
Cannot register, delete or change the multi-control setting during using the network viewer func-
tion.
It is recommended that a specified monitor should be chosen for setting as a master when you
use this multi-control function. The control for the multi-controlled monitors will become too
complicated operation if this function is used for each monitor.
If the registered monitor is not connected to the network, it will take some time to complete the
multi-control operation because of waiting for the response from each registered monitor.
There are some disabled items in the multi-control function for the light mode.
Change the mode of the registered monitor
To change the mode of the registered monitor, select a mode with the pull-down menu
button under the IP address of the target monitor and then click Set button.
Status Description
(blank) ..................... The monitor is connected to the network correctly
No connect .......... The monitor may not be connected to the network. Please check the connection
and network configuration of this monitor.
PIN code error ............. The PIN code is incorrect. The PIN code for the multi-controlled monitors must be
the same. Change the PIN code of this monitor to the common PIN code.
File Error
................. Not displaying the images. Check if this monitor is using the Network Capture func-
tion or Network Viewer function individually, or in the standby mode.
* The network unit updates the status at the time when the multi-control function was executed.
Mode Operation
Control .................... Controlling the monitor
Both control ........ Controlling and displaying pictures
Visual
control .......... Displaying the pictures
OFF ............................ Excluding from the multi-control
Delete ...................... Deleting from the multi-control
Status
* The multi control item is not changed during using the
network viewer function. It is not available with the light
mode.