SATO CL408-412e Printer User Manual


 
Unit 4: Printer Configuration
CL408-412e Supplemental Manual
4-18 PN: 9001159A
MAINTENANCE MODE
The Maintenance Mode permits counter reset of various printer components. Use the printer’s operator panel to
select and enter the required options.
The printer has integrated counters to measure the accumilative activity of some features. The unit of measure is
based on linear meters and includes a print head counter and a life counter. The head counter records the length of
the media that has been printed since the print head was installed and should be reset each time the print head is
replaced.
The life counter meaures the lenght of media the printer as a whole has printed. This counter would only be reset in
case circuitry replacement.
The printer’s Counter Mode allows the operator to view the accumilated measurement and also allows the print
head counter to be reset to zero.
Refer to the Menu Definition Tables in the following chapter to provide an explanation of each menu screen.
Figure 4-13, Maintenance Mode
Printer
performs
factory test
print
TEST PRINT
PRESS FEED KEY
PRINT SIZE
SMALL LARGE
ALL CLEAR MODE
Reset
DSW4: OFF
MAINTENANCE MODE
DIPSW2-4 ON->OFF
DSW4: ON
LINE +FEED + POWER
No action,
no change
FEEDLINE
No action,
no change
FACTORY MODE
FEEDLINE
COUNTER CLEAR
NONE
ALL
HEAD
FEEDLINE
ALL CLEAR
COUNTER EEPROM
LINE
FEED
Scrolls
options
LINE
FEED
Scrolls
options
LINE
FEED
No action,
no change
Power printer
off to exit
LINE
Scrolls
options
Counter
FEED
EEPROM
FEED
COUNTER ALLCLEAR
YES NO
EEPROM ALLCLEAR
YES NO
LINE
Scrolls
options
No
FEED
Yes
FEED
LINE
Yes
FEED
No
FEED
COUNTER ALLCLEAR
COMPLETED
EEPROM ALLCLEAR
COMPLETED