SATO CX Series Printer User Manual


 
98
SATO CX Series Printer
A Protocol Command code status label will be printed as a re-
sult of the a successful download of a custom set of Protocol
Command codes.
Special Notes:
1. Commas must be used to separate the parameters. If a
parameter is omitted between two commas, the default
Non-Standard Protocol Command codes for that para-
meter will be used.
2. This command must be sent as an independent data
stream immediately following the <ESC>A Start code
and immediately preceding the <ESC>Z Stop code. No
other commands can be included in the data stream.
3. If more or less than nine commas are included in the
command, the entire command sequence will be igno-
red. The command must contain exactly nine commas.
4. If two characters are specified for a parameter, it will be
interpreted as a hex value.
5. If a combination of characters are outside the hexadeci-
mal range, the entire command sequence will be igno-
red.
6. The current protocol command codes may be verified by
printing a self test label (<ESC>CT).
STX=7B
ETX=7D
ESC=25
ENQ=23 CAN=26 NULL=2A
OFFLINE=7E
Press the "FEED" key to activate the User
Defaults, or Power OFF to ignore them.