104
SATO CX Series Printer
Set RS232 Parameters
Set RS232 ParametersSet RS232 Parameters
Set RS232 Parameters
Command Structure
<ESC>CRaaaaa,b,c,d
aaaaa = Baud Rate (2400, 4800, 9600 or 19200)
b = Parity (N for None, O for Odd, E for Even)
c = Number of data bits (7 or 8
d = Number of stop bits (1 or 2)
Example:
<ESC>CR9600,N,8,1
Placement: Must be sent in a separate data stream.
Default: 9600,N,8,1
Command Function
To select the desired RS232 communications settings
Input to Printer
<ESC>A
<ESC>CR9600,N,8,1
<ESC>Z
Printer Output
There is no printer output as a result of this command.
Special Notes
1. Any commands sent to the printer over the RS232 port
within two seconds of receiving this command may be
lost.
2. The RS232 settings must match those of the host system.
If the RS232 settings are unknown, printing a Self Test
label will list the current printer settings.