INTERFACE SELECTION
This unit presents the printer interface types and their specifications. These specifications include detailed
information to assist in the selection of the most appropriate method for the printer to interface with the host. The
five acceptable interface methods are:
RS232C High-Speed Serial
IEEE1284 Parallel
Universal Serial Bus (USB)
Local Area network (LAN) Ethernet
802.11g Wireless
Following the selection of the desired interface, proceed to the next unit for instructions on how to configure the
printer for that interface type.
RS232C HIGH-SPEED SERIAL INTERFACE
Figure 3-5, Serial Connector Pin Assignments
WARNING: NEVER CONNECT OR DISCONNECT INTERFACE CABLES (OR USE
A SWITCH BOX) WITH POWER APPLIED TO EITHER THE HOST OR THE
PRINTER. THIS MAY CAUSE DAMAGE TO THE INTERFACE CIRCUITRY IN THE
PRINTER/HOST AND IS NOT COVERED BY WARRANTY.
INTERFACE SPECIFICATIONS
Asynchronous ASCII Half-duplex communication
Bi-Directional Communication
Data Transmission Rate 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps
Transmission Form Start, b1, b2, b3, b4, b5, b6, b7, b8, Stop (b8 will be omitted if using 7 bit oriented)
Data Length 7 or 8 bit (selectable)
Stop Bit 1 or 2 bit (selectable)
Parity Bit ODD, EVEN, NONE (selectable)
Codes Used ASC II Character Codes: 7 bits, Graphics: 8 bits
Control Codes STX (02H), ETX (03H), ACK (06H), NAK (15H)
Connector (Printer Side) DB-9 Male (equivalent), 9-pin Serial Interface (PCI)
Cable Connector DB-9 Female (equivalent), 9-pin Serial Interface (PCI)
Cable Length 5 meters or less.
Signal Levels High = +5V to +12V, Low = -5V to -12V
Protocol Ready/Busy, X-On/X-Off, Protocol for Driver, Status2, Status3, Status4, Status5