Schneider Electric KVM2116P Switch User Manual


 
57KVM Switch KVM2132P, KVM2116P, KVM1116P User Manual
Configuration
Configure an outlet's settings directly from this page by clicking the Configuration button to open the
PDU Outlet Configuration dialog box.
Configuration options.
Heading Explanation
Station The name of the device to which the outlet belongs.
Port The outlet's current name.
Name Enter a name for the outlet. The maximum number of characters is 15.
Power On Delay Set the amount of time the PDU waits after the Power Button is clicked before turning on
the computer attached to the corresponding outlet.
The default delay time is 0 seconds. The maximum is 7200 seconds.
Power Off Delay • Set the amount of time the PDU device waits after the Power button is clicked before
shutting down the computer attached to the corresponding outlet.
• The default delay time is 0 seconds. The maximum delay time is 7200 seconds.
Power Reboot Delay • Set the amount of time the PDU waits after the computer is shutdown before turning on the
computer attache to the corresponding outlet.
• The default delay time is 5 seconds. The maximum delay time is 60 seconds.