Schneider Electric VW3A3310d Network Card User Manual


 
66
16. Downloading from the web server
Each URL in the HTTP server is stored in the file table. As a result, the user can easily change the standard web server by adding, deleting
or modifying the URL files.
However, some URLs are required and/or cannot be modified.
The “index.htm”, “html/english/home/index.htm” and “html/english/home/home.htm” pages, which form the entry page to the web server, are
compulsory.
The WebServer.htm page (see later), and the various HTML requests, such as password modification, are fixed and are not visible via
the FTP server.
The maximum file size is limited to 64 Kb. The size of the AtvSys.jar java archive file, containing the java applets, is almost 64 Kb.
If additional java applets are required, two archive files must be created.
b Web server
The web server has a masked page, which cannot be accessed directly via a hyperlink, providing access to a summary of the memory
resources, sector by sector, used by the web server.
Example of access: http://192.168.1.23/WebServer.htm
Memory Sector Free (bytes) Max (bytes) FastFree (bytes) # File
Sector 12 1,429 65,536 1,429 44
Sector 13 237 65,536 237 01
Sector 14 18,516 65,536 18,516 02
Sector 15 65,536 65,536 65,536 00
Sector 16 65,536 65,536 65,536 00
Sector 17 65,536 65,536 65,536 00
Sector 18 65,536 65,536 65,536 00
Sector 19 65,536 65,536 65,536 00
Sector 20 65,536 65,536 65,536 00
Sector 21 65,536 65,536 65,536 00
Sector 22 65,536 65,536 65,536 00
Sector 23 65,536 65,536 65,536 00
Sector 24 65,536 65,536 65,536 00
Sector 25 65,536 65,536 65,536 00
Sector 26 65,536 65,536 65,536 00
Sector 27 65,536 65,536 65,536 00
Sector 28 65,536 65,536 65,536 00
Sector 29 65,536 65,536 65,536 00
Sector 30 65,536 65,536 65,536 00
Sector 31 65,536 65,536 65,536 00
Sector 32 65,536 65,536 65,536 00
Sector 33 65,536 65,536 65,536 00
Sector 34 65,536 65,536 65,536 00
TOTAL 1,330,902 1,507,328 1,330,902 47