(16) Initializing the bar code mode: DC4 DC4 @
Format: ASCII DC4 DC4 @
Hex 14 14 40
Decimal 20 20 64
Function: Initializes the bar code mode.
The following show the default settings for bar code.
Bar code type: SETUP
Narrow bar width: SETUP
Wide bar width: SETUP
Narrow space width: SETUP
Wide space width: SETUP
Inter- character gap: SETUP
Bar code height: SETUP
Setting HRI: Below the bar code symbol
HRI font OCR-B
Check character: Added
Printing density: 1/120”
Data processing in the bar code data sequence
In a bar code data sequence following ESC SI, any codes
other than the ESC code are regarded as bar code data.
Continuous two-byte ESC codes (ESC + ESC) are
regarded as a one-byte ESC bar code.
In a barcode data sequence following ESC SI, SO ESC+
SI and ESC + ESC are valid and the other ESC sequence
are ingnored. The ESC code and the following data, two
bytes in all, are discarded.
When a start or stop character code (e.g., ‘*’ code of
Code 39) is input in a bar code data sequence, the bar
code data sequence stops if bar code data has already
been input in that sequence. The data that was input is
valid (and converted into a bar code). If not, the bar code
data sequence does not stop and the code is discarded.
When 68 bytes of data is input, the bar code data
sequence ends automatically.
When Code 93 or Code 128 is selected, the bar code data
sequence ends when the amount of input data, including the
automatically inserted control character, reaches 68
75
9. Bar code and enlarged character