Sharp UP-810F Cash Register User Manual


 
41
Scale entries
You have a choice of either the manual or automatic method for scale entry.
If the first method is chosen, the clerk needs to enter the reading of the scale manually. If the second one is
chosen, the weight is automatically read from the connected scale (option) and appears in the POS terminal
display. If you need manual scale entries, contact your authorized SHARP dealer.
Auto scale entries
FF method
Normal method
• Tare weight: Up to 4 digits (integer + decimal)
• Net weight: Up to 5 digits (integer + decimal)
• Base weight: Up to 2 digits (integer)
• Scale table number: 1 to 9
• The POS terminal can be programmed with up to nine scale tables and allows different tares to
be assigned to them.
• When the
S
key is pressed, the net weight is automatically read from the connected scale
(option) and appears in the POS terminal display.
• When the PLU is programmed for “Compulsory scale entry,” it is not necessary to press the
S
key.
• To issue a receipt which shows only a tare weight, press
o
, enter a tare weight, then press
S
and
c
.
• The currency descriptor is displayed/printed when it is programmed for the CHECK.
NOTE
Scale table number
Tare weight
When you use a
programmed scale
table number.
Item selection
thru Tare weight
Unit price
per base wt.
o
e
Base wt.
When you use a
base wt. programmed
for PLU code
Scale table number
When you use a
programmed scale table no.
oBA
Base wt.
When base wt. is 1 kg
(or 1 lb.)
When you use a
base wt. programmed
for PLU code
x
S
Unit price
per base wt.
Department key
When you use a programmed
unit price
Unit price Dept.code
Unit price
per base wt.
PLU code
Department key
Unit price
per base q’ty
Direct PLU
Unit price
per base q’ty
s
Unit price Dept.code
`
`
à
PLU code
s
S
Direct PLU
Base wt.
Scale table number
Tare weight
When you use a
programmed scale
table number.
When you use a
base wt. programmed
for PLU code
o
S
Procedure