102
■
Display
Procedure
Program each item as follows:
•POWER SAVE (Use the numeric entry)
Time of the power save (2 digits: 1 to 99 minutes,
0:100minutes).
•P. SAVE AT TM (Use the selective entry)
Power saving during time display:
YES: Enables power saving during time display.
NO: Disables power saving during time display.
■
Printer
Procedure
Program each item as follows:
•DENSITY(Usethenumericentry)
Select a density level (2 digits: 00 to 99).
00: 89% for standard
50: 100% for standard
99: 111% for standard
■
Online
Procedure
Program each item as follows:
The screen continues.
•TERMINAL No. (Use the numeric entry)
Terminal number (6 digits: 0 to 999999).
•CISIGNAL(Usetheselectiveentry)
Sensing of the CI signal
NON: Disables sensing of the CI signal.
SENSING: Enables sensing of the CI signal.
•LINE FORM (Use the selective entry)
Programming of the modem control
FULL: Full duplex system.
HALF: Half duplex system.
•BAUD RATE (Use the selective entry)
Transmission data rate.
38400 bps 19200 bps
9600 bps 4800 bps
•START CODE (Use the numeric entry)
Start code (3 digits: 0 to 127)
•END CODE (Use the numeric entry)
End code (3 digits: 0 to 127)
•TIME OUT (Use the numeric entry)
Programming of the time-out time (3 digits: 1 to 255 sec.)