Sony MZ-E800 Microcassette Recorder User Manual


 
13
Configuration of Test Mode
Manual Mode
Mode to adjust or check the operation of the set by function.
Normally, the adjustment in this mode is not executed.
However, the Manual mode is used to clear the memory and power
supply/charging adjustments before performing automatic
adjustments in the Overall Adjustment mode.
Transition method in Manual Mode
1. Setting the test mode (see page 12).
2. Press the
[VOL +] key activates the manual mode where the
LCD display as shown below.
3. During each test, the optical pick-up moves outward or in-
ward while the N > or . key is pressed for several
seconds respectively.
4. Each test item is assigned with a 3-digit item number;
100th place is a major item, 10th place is a medium item, and
unit place is a minor item.
[Manual Mode]
[Servo Mode]
[Audio Mode]
[Power Mode]
[OP Alignment Mode]
[Overall Adjustment Mode]
[Self-Diagnosis Display Mode]
Press the [VOL +] key
[Key Check Mode]
[Test Mode $Display Check Mode%]
Press the
x
key
Press the
x
key
Press the
x
key
Press the
.
or [VOL --] key
press the [DISPLAY] key
Press the
[DISPLAY] key
for several seconds (about 3 seconds).
Quit the key check
Remote commander LCD display
000 Manual
[VOL +] key:100th place of item number
increase.
[VOL --] key:100th place of item number
decrease.
[Major item switching]
[VOL +]
key:10th place of item number
increase.
[VOL --] key:10th place of item number
decrease.
[VOL +] key:Increases the
adjusted value
[VOL --] key:Decreases the
adjusted value
[Medium item switching]
N
key
>
N
key
>
x key
[Minor item switching]
[Adjusted value variation]
X key:When adjusted value is
changed:
Adjusted value is written.
When adjusted value is
not changed:
That item is adjusted
automatically.
[Adjusted value write]
N
key: Unit place of item number
>
increase.
x key