Symantec HP-UX Computer Drive User Manual


 
43Upgrading the product
Upgrading from 3.5 to 5.0
8 Uninstall VCS 3.5 from all the nodes. Run the following commands from one
of the nodes.
See the Veritas Cluster Server Installation Guide.
# cd /opt/VRTSvcs/install
# ./uninstallvcs
Note: Ignore any errors from the uninstallvcs script and proceed with
the uninstall of VCS.
9 Upgrade the operating system from HP-UX 11i Version 1 to HP-UX 11i
Version 2 on all the nodes.
See the HP-UX Operating System documentation.
10 Install all the prerequisite patches on all the nodes. See section “Required
HP-UX patches” on page 15.
11 Install SFCFS 5.0 and reboot all the nodes.
See “Installing the product” on page 19.
Note: Do not configure SFCFS after reboot.
12 Start vxfen on all the nodes. vxfen can be started either in disable or enable
mode. For starting
vxfen in disabled mode, run the following commands:
# cat vxfen_mode=disabled > /etc/vxfenmode
# /sbin/init.d/vxfen start
See the Veritas Cluster Server Installation Guide for information regarding
starting
vxfen in enabled mode.