Tannoy ACTIVE STUDIO MONITORS Computer Monitor User Manual


 
27
Parameter Description
Basic operation in all menus (when navigating the menus via the LCD display)
Use ARROW keys to select value or submenu
Use ENTER to enter menus or for confirmation, and to activate
Use EXIT to step to a higher level or to decline an operation
Values are marked with an “ * “ when they can be altered via the ARROW keys
Main Display
The Main Display indicates the position of the monitor (when set up) and the set volume for the monitor.
A “+” symbol indicates that this specific Master Unit has been set up to act as System Controller.
Bass Management †
Bass management is possible in:
- Standard Stereo with 1 Sub
- Standard Stereo with 2 Subs
- All surround modes
The Precision monitors utilize 2nd order Hi Pass filters to attenuate frequencies below the set crossover frequency.
The subwoofer utilises 4th order Low Pass filter to attenuate frequencies above the set crossover frequency.
Press ENTER to access the Select Mode
Off - Bass Management is not activated. Only the LFE channel is distributed to the Sub.
Available Crossover Frequencies:
Menu Name Precision Filter Sub 4
th
Order Sub 2
nd
Order LFE = Sub
X-Over 50 Hz 50Hz 50Hz 50Hz No
X-Over 80 Hz 80Hz 80Hz 80Hz No
Extension 50 Hz Off 50Hz 50Hz No
Extension 80 Hz Off 80Hz 80Hz No
THX Sim 80 Hz 80Hz 80Hz Off Yes
Small Cons 120 Hz †† 120Hz 120Hz 80Hz Yes
† PC-iP
Via the iDP PC-iP
installer package (optional software for the advanced installer) an advanced Bass Management mode
is available. In this mode a greater number of frequencies can be chosen, and all filters (Precision HPF, Sub 4th order
and Sub 2nd order) can be controlled to suit demanding & critical setups.
†† Small Cons - Small Consumer (filter to mimic a small consumer speaker)