Tannoy ACTIVE STUDIO MONITORS Computer Monitor User Manual


 
49
iDP
Display Messages
The following is an explanation of Error Messages, etc may appear on a Master monitor Display:-
"!" as "96 kHz Center!”
The "!" indicates that the monitor is not connected to the network. The volume is then automatically set to -50 dB for the
monitor not recognized in the network.
"+" as "96 kHz L Front+":
The "+" indicates that the monitor you are looking at is the System Controller.
>> A-Input Lo <<
This message is displayed in analog setups only and indicates that the Input level has been detected to be between -
60dB and -20dB for a period longer than 3 minutes. This is an indication to increase the Analog Input Gain.
Analog Input gain range:
+9dBu, +15dBu, +21dBu or 27 dBu.
>> A-Input Hi <<
This message is displayed in analog setups only and indicates that an Input level near 0dB is detected. (peaks @ 2 sec.
Above -1 dB). This is a warning and you should turn down the Analog input gain
Analog Input gain range:
+9dBu, +15dBu, +21dBu or 27 dBu.
>> PSU error <<
Displayed if the power supplies fails. The power will be turned off and the monitor will operate. Contact TANNOY Service
Department.
<Locked>
Displayed when a parameter is locked by the PC-iP
installer software and cannot be changed.
Parameter lock can only be unlocked with the PC-iP
software.
Standby
Displayed when no Input signal has been detected for the time specified in the Utility Menu. below -65 dB. The Amplifier
is turned off. Standby mode is released as soon a signal level above -65dB has been detected.
>> Power save <<
Displayed when no signal has been detected on all monitors on the network for the time specified in the Utility Menu.
Power is turned off. Exit this mode by pressing any key on system controller or adjusting volume from the remote.