CHAPTER 2 SPECIFICATIONS
2.1OUTPUT RATING
MODEL
GEN
6-100
8-90
12.5-60
20-38
30-25
40-19
60-12.5
80-9.5
100-7.5
150-5
300-2.5
600-1.3
1.Rated output voltage(*1)
V
6
8
12.5
20
30
40
60
80
100
150
300
600
2.Rated output current 750W (*2)
A
100
90
60
38
25
19
12.5
9.5
7.5
5
2.5
1.3
3.Rated output power750W
W
600
720
750
760
750
760
750
760
750
750
750
780
MODEL
GEN
6-200
8-180
12.5-120
20-76
30-50
40-38
50-30
60-25
80-19
100-15
150-10
300-5
600-2.6
1.Rated output voltage(*1)
V
6
8
12.5
20
30
40
50
60
80
100
150
300
600
2.Rated OutputCurrent 1500W(*2)
A
200
180
120
76
50
38
30
25
19
15
10
5
2.6
3.Rated output power1500W
W
1200
1440
1500
1520
1500
1520
1500
1500
1520
1500
1500
1500
1560
2.2INPUT CHARACTERISTICS
V
6
8
12.5
20
30
40
50
60
80
100
150
300
600
1. Input voltage/freq. (*3)
2. Input current (at100/200Vac)
A
3. PowerFactor
4. 750Wmodels Efficiency (*4)
%
76/78
77/80
81/84
82/85
82/85
83/87
83/87
83/87
83/87
83/87
83/87
83/87
83/87
5. 1500W modelsEfficiency (*4)
%
77/79
78/81
82/85
83/86
83/86
84/88
84/88
84/88
84/88
84/88
84/88
84/88
84/88
6. Inrush current at 100/200V
A
2.3 CONSTANTVOLTAGEMODE
V
6
8
12.5
20
30
40
50
60
80
100
150
300
600
1. Max.Line regulation (*5)
2. Max.Load regulation(*6)
3. Ripple andnoise(p-p,20MHz)(*10)
mV
60
60
60
60
60
60
60
60
80
80
100
150
300
4. Ripple r.m.s.,5Hz~1MHz(*10)
mV
8
8
8
8
8
8
8
8
8
8
10
25
60
5. Temperaturecoefficient
PPM/°C
100PPM/°Cof ratedoutput voltage,following30 minuteswarmup
6. Temperaturedrift
7. Rem. Sensecompensation/wire
V
1
1
1
1
1.5
2
2
3
4
5
5
5
5
8. Up-prog. Responsetime0~Vomax(*9)
mS
250
9. Down-prog. Responsetime: Full load
mS
10
250
No load
500
600
700
800
900
1000
1100
1100
1200
1500
2000
2500
4000
10.Transientresponsetime
mS
11.Hold-up time
mS
2.4CONSTANT CURRENTMODE
V
6
8
12.5
20
30
40
50
60
80
100
150
300
600
1. Max.line regulation(*5)
2. Max.load regulation(*7)
3. Ripple r.m.s. 5Hz~1MHz.750W(*8)
mA
200
180
120
76
63
48
38
29
23
18
13
8
1500W(*8)
mA
400
360
240
152
125
95
75
75
57
45
35
25
12
4. Temperaturecoefficient
PPM/°C
5. Temperaturedrift
2.5ANALOGPROGRAMMINGANDMONITORING
1.Voutvoltageprogramming
2. Ioutvoltage programming
3. Vout resistorprogrmming
4. Ioutresistorprogramming
5. On/off control
6. Output current monitor
7. Output voltage monitor
8. PowersupplyOKsignal
9. Paralleloperation
10.Seriesoperation
11.CV/CCinicator
12.Enable/Disable
13.Local/Remoteanalogcontrol
14.Local/remote analog indicator
Dry contact. Open: off,Short: on.Max. voltage at Enable/Disable in: 6V.
Byelectrical signal or Open/Short: 0~0.6Vorshort: Remote,4~5Voropen: Local.
Opencollector. Local:Open, Remote: On. Maximum voltage: 30V, maximum sink current: 5mA.
4~5V-OK,0V-Fail, 500ohmseriesresistance.
Possible,up to 4units in master/slavemode withsingle wirecurrent balance connection.
Possible (withexternal diodes), upto 2units.
CV: TTL high(4~5V),sourcecurrent: 10mA, CC: TTL low(0-0.6V).Sinkcurrent: 10mA .
Timefortheoutput voltageto recoverwithin0.5%of itsratedoutputfora loadchange 10~90%ofrated
Byelectrical Voltage:0~0.6V/2~15Vordrycontact, userselectablelogic.
0~5V or 0~10V, user selectable.Accuracy: 1%
0~5V or 0~10V, user selectable.Accuracy: 1%
100PPM/°Cfromratedoutput current,following 30minuteswarm-up.
0.05% of ratedlout over 8hrs interval following30 minuteswarm-up. Constant line, load &temp.
output current.
Outputset-point: 10~100%.
Less than1mSfor modelsupto andincluding100V;2mS formodels above100V.
85~265Vac continuous, 47-63Hz, singlephase.
10.5/5for750Wmodel, 21/11for1500Wmodels.
0.99@100/200Vac, rated output power.
Less than25Afor750W models, 50Afor1500Wmodels.
0.01% of ratedoutput voltage+2mV
0.01% of ratedoutput voltage+2mV
0.05% of ratedVout over8hrs interval following 30 minuteswarm-up. Constant line, load&temp.
50
80
150
80
150
Morethan 20mS,100Vac, rated output power.
0.01% of ratedoutput voltage+2mA
0.02% of ratedoutput current +5mA
0~100%,0~5Vor0~10V,userselect. Accuracyand linearity; +/-0.5% of ratedVout.
0~100%,0~5Vor0~10V,userselect. Accuracyand linearity; +/-1%of ratedIout.
0~100%,0~5/10Kohm full scale, user select.Accuracyandlinearity:+/-1%of ratedVout.