TDK 1500W Power Supply User Manual


 
83
-
507
-
013 Rev. D
10
1. Vout programming accuracy
2. Iout programmingaccuracy (*13)
3. Vout programming resolution.
4. Iout programmingresolution
5. Vout readback accuracy
6. Iout readbackaccuracy(*13)
7. Vout readback resolution
8. Iout readbackresolution
2.7PROTECTIVEFUNCTIONS
V
6
8
12.5
20
30
40
50
60
80
100
150
300
600
1. Foldbackprotection
2. Over-voltage protection
3. Over-voltage trip point
V
0.5-7.5
0.5-10
1-15
1-24
2-35
2-44.1
5-57
5-66
5-88
5-110
5-165
5-330
5-660
4. Output undervoltagelimit
5. Over temperature protection
2.8FRONT PANEL
1. Control functions
2. Display
Vout:
Iout:
3. Indications
2.9ENVIRONMENTALCONDITIONS
1. Operatingtemperature
C
2. Storage temperature
C
3. Operatinghumidity
%
4. Storage humidity
%
5. Altitude
2.10MECHANICAL
1. Cooling
2. Weight
Kg
3. Dimensions(W xH xD)
mm
4. Vibration
5. Shock
2.11SAFETY/EMC
1. Applicablestandards Safety
EMC
2. Withstandvoltage
3. Insulation resistance
4. Conductedemission
5. Radiated emission
Morethan 100Mohmat 25°C,70%RH
EN55022B, FCCpart 15-B,VCCI-B
EN55022A, FCCpart 15-A,VCCI-A
2.6PROGRAMMINGANDREADBACK(RS232/485, Optional IEEEInterface)
0.05%+ 0.05%of ratedoutputvoltage.
0.1%of actual output current+ 0.1%of ratedoutput current (for Iout >0.4%of rated Iout to 100%ofratedIout).
0.1%of actual output current+0.4%of rated output current (forIout <0.4%ofratedIout to0.4%of rated Iout).
0.012%of full scale.
0.012%of full scale.
0.1%+0.1%of rated output voltage
0.1%+0.3%of rated output current
0.012%of full scale
0.012%of full scale
Output shut-downwhen powersupplychanges fromCVto CC. User presetable.
Invertershut-down; manual reset byACinputrecycle,OUT button.
Presetbyfront panelor communicationport. Prevents adjusting Vout belowlimit.Raises thePS_OKsignal incase
output voltageisbelowlimit.
Userselectable,latched or non latched.
Vout/Iout manual adjustby separateencoders. (Coarseandfine adjustment)
OVP/UVL manual adjustbyVolt. Adjust encoder
Address selection byVoltage adjust encoder. No of addresses: 31
Goto local control
Output on/off
ACon/off
Front panel lock
Foldback control
Serial or IEEE displayat power-up
Baud rate selection: 1200, 2400, 4800, 9600 and 19200
Re-start modes(AutoRestart, Safe Start)
4 digits, accuracy:0.5%of rated voltage +1 count
30~90%RH (nocondensation).
4 digits, accuracy:0.5%of rated current +1 count
VOLTAGE, CURRENT,ALARMFINE, PREVIEW, FOLDBACK, LOCAL, OUTPUTON.
0~50C, 100%load.
-20 to+ 70
10~95%RH (nocondensation).
Maximum3000m, Derateoutput current by 2%/100mabove2000m. Alternatively, derate maximumambient
temperatureby1 degC/100mabove2000m.
Forcedair cooledby internal fans.
Less than4.5Kg
W:214.0H: 43.6 (57.0BenchtopVersion). D:437.5(Refer toOutlinedrawing).
MIL-810E, method514.5test conditionl-3.3
Less than20G, halfsine, 11mS.Units unpacked
UL 60950-1listed,EN60950-1Vout <=40V: Outputis SELV, IEEE/IsolatedAnalogareSELV.
60<Vout <400V:Output is hazardous, IEEE/Isolated analog areSELV
400< Vout< 600V: Output ishazardous,IEEE/Isolated,Analog arenotSELV
EN55024
Vout <60Vmodels: Input-Outputs(SELV): 3.0KVrms1min, Input-Ground: 2.0KVrms1min.
60 <=Vout< 600Vmodels: Input-Haz,output: 2.5KVrms1min, Input-SELV: 3KVrms1 min, 1900VDC1 min.
HazardousOutput -SELV: 1.9KVrms 1min, Hazardous Output-Ground: 1.9KVrms1 min.
Input-Ground: 2KVrms1min