83
-
507
-
013 Rev. D
18
3.8.7
Foldback Check
Refer to Section 5.5 for explanation of the FOLD function prior to performing the procedure bel
ow.
1.
Ensure that the Output Voltage is set to approx. 10% of the unit rating.
2.
Adjust the CURRENT encoder to set the Output Current setting to approx. 10% of the unit rating.
3.
Momentarily press the FOLD button. Ensure that the FOLD LED illuminates. The Output
Voltage
remains unchanged.
4.
Short the output terminals momentarily (approx. 0.5 sec.). Ensure that the Output Voltage falls to
zero, the VOLT display shows “Fb” and the ALARM LED blinks.
5.
Press the FOLD button again to cancel the protection. The Output Volt
age remains zero.
6.
Press the OUT button. Ensure that the Output Voltage returns to its last setting.
7.
Turn the output off by pressing the OUT button. Ensure that the VOLT display shows “OFF”.
3.8.8
Address Setting
1.
Press and hold the REM/LOC button for approx. 3 s
ec. The VOLT display will show the commun
i-
cation port address.
2.
Using the VOLT adjust encoder, check that the address can be set within the range of 0 to 30.
3.8.9
Baud Rate Setting (RS
-
232 and RS
-
485 only)
1.
Press and hold the REM/LOC button for approx. 3 sec. The
CURRENT display will show the
communication port Baud Rate.
2.
Using The CURRENT adjust encoder, check that the Baud Rate can be set to 1200, 2400, 4800,
9600 and 19200.
3.9 CONNECTING THE LOAD
3.9.1
Load Wiring
The following considerations should be mad
e to select wiring for connecting the load to the power su
p-
ply:
Current carrying capacity of the wire (refer to Section 3.9.2)
Insulation rating of the wire should be at least equivalent to the maximum output voltage of the
power supply.
Maximum wire lengt
h and voltage drop (refer to Section 3.9.2)
Noise and impedance effects of the load wiring (refer to Section 3.9.4).
3.9.2
Current Carrying Capacity
Two factors must be considered when selecting the wire size:
1.
Wires should be at least heavy enough not to overhea
t while carrying the power supply load
current at the rated load, or the current that would flow in the event the load wires were
shorted, whichever is greater.
WARNING
Shorting the output may e
xpose the user to hazar
d
ous
voltages. Observe proper safety procedures.
WARNING
Turn Off the AC input power bef
ore making or changing any
rear panel connection. Ensure that all connections are s
e-
curely tightened before applying power. There is a potential
shock hazard when using a power supply with a rated ou
t-
put greater than 40V.