Remote sensing
Use remote sense where the load regulation at the load end is critical. In remote sense, the power
supply will compensate for voltage drop on the load wires. Refer to the power supply specific
a
tions for
the maximu
m voltage drop on load wires. The voltage drop is subtracted from the total voltage avai
l-
able at the output. Follow the instructions below to configure the power supply for remote sensing:
1.
Ensure that the AC On/Off is in the Off position.
2.
Remove the local
sense jumpers from J2.
3.
Connect the negative sense lead to terminal J2
-
5 (S) and the positive sense lead to term
i
nal J2
-
1(+S) of the J2 mating connector. Ensure that the J2 mating connector is plugged securely into
the rear panel sense connector, J2.
4.
Turn O
n the power supply.
Notes:
1.
If the power supply is operating in remote sense and either the positive or negative load wire is not
connected, an internal protection circuit will activate and shut down the power supply. To resume
operation, turn the AC On/Off
to the Off position, connect the open load wire, and turn On the
power supply.
2.
If the power supply is operated without the remote sense lines or local sense jumpers, it will co
n-
tinue to work, but the output voltage regulation will be degraded. Also, the O
VP circuit may act
i-
vate and shut down the power supply.
3.10.4 J2 sense connector technical information
-
J2 connector type: MC 1.5/5
-
G
-
3.81, Phoenix.
-
Plug type: MC 1.5/5
-
ST
-
3.81, Phoenix.
-
Wire AWG; 28 up to 16.
-
Stripping length: 7mm (0.28 inches).
-
Tighteni
ng torque: 0.22
-
0.25Nm (1.95
-
2.21Lb
-
Inch.)
3.11 REPACKAGING FOR SHIPMENT
To ensure safe transportation of the instrument, contact the TDK
-
Lambda Americas Inc. sales or se
r-
vice facility near you for Return Authorization and shipping information. Please att
ach a tag to the
power supply describing the problem and specifying the owner, model number and serial number of
the power supply. Refer to Wa
r
ranty Information for further instructions.
WARNING
There is a potential shock hazard at the sense point when using a power supply
with a r
ated Output Voltage greater than 40V. Ensure that the connections at the
load end are shielded to prevent accidental contact with hazardous voltages.
CAUTION
Whe
n using shielded sense wires, ground the shield
in one place only. The location can be the power
supply chassis or one of the output terminals.