Texas Instruments TMS470R1x Barcode Reader User Manual


 
DOS/4G Error Messages
A-9
Troubleshooting DOS Systems
A.3 DOS/4G Error Messages
DOS/4G errors are more common than kernel errors when using DOS/4G or
DOS/4GW with the TMS470R1x code generation tools. They are usually re-
lated to an unknown path name, corrupt files, or memory problems. Memory
problems can include inadequate memory, poor configuration, or corrupted
memory.
1000 ”can’t hook interrupts”
Description
A DPMI host has prevented DOS/4G from loading.
Action
Contact technical support.
1001 ”error in interrupt chain”
Description
A DOS/4G internal error was detected.
Action
Contact technical support.
1003 ”can’t lock extender kernel in memory”
Description
DOS/4G could not lock the kernel in physical memory, prob-
ably because of a memory shortage.
Action
Free some memory for the DOS/4G application.
1005 ”not enough memory for dispatcher data”
Description
There is not enough memory for DOS/4G to manage user-
installed interrupt handlers properly.
Action
Free some memory for the DOS/4G application.
1007 ”can’t find file <program> to load”
Description
DOS/4G could not open the specified program. The file prob-
ably does not exist. It is possible that DOS ran out of file han-
dles or that a network or similar utility has prohibited read ac-
cess to the program.
Action
Make sure that the filename was spelled correctly.
1008 ”can’t load executable format for file <filename> [<error
code>]”
Description
DOS/4G did not recognize the specified file as a valid execut-
able file. DOS/4G can load linear executables (LE and LX)
and EXPs (BW).
Action
Recopy the file from the source media.