TOA Electronics NX-100 Network Cables User Manual


 
3-4
Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM)
3. SETTING PROCEDURE
Pattern 1: Initial On-Site Setup
(1) Unit Scanning (Network Setting)
After scanning the unit using the Setup program's Unit Scanning Tool, set the IP address, default
gateway, subnet mask, and unit name.
Upload the network setting data.
Save the network setting data in unit setting file format ([IP address].cfg).
(2) System Setting
Set non-network items using the System Setting Tool.
Manually add any units that could not be scanned, and enter their IP addresses and unit names.
Set the following items in the order listed:
System: Set audio I/O unit names.
Network: Set the port number.
Broadcast Spec: Perform Broadcast Spec settings based on the network configuration.
Before using this function, confirm the following information with network
management personnel:
· Usable bandwidth
· Whether or not multicast streaming can be used
Broadcast Pattern: Set the units to be connected in each broadcast pattern when activated by
contact or the Operation program. (This setting not needed for units that will not
be used in broadcast patterns.)
• Contact: Set the broadcast pattern to be activated when a contact is received, and the
contact output for other connected units. Also, set the operation to be
performed when contact output is activated by other units.
Serial Bridge : Set the units to be connected and their serial ports when using the
serial bridge function.
NX-100 only
(3) Setting Upload
Upload the unit setting file in order to enable the settings set in Step (2) above.