TOA Electronics NX-100 Network Cables User Manual


 
3-10
Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM)
5.2.3. Help
Help: Displays help contents.
Version data: Indicates the version of the program in use.
5.3. Buttons
(1)
(2)
(1) Unit scan button: Scans all the units on the LAN.
(2) Setting upload button: Writes the IP address, subnet mask, default gateway, and name into the selected
units.
5.4. Scanning Units
Scans each unit connected to the LAN.
Step 1. Connect NX-100 and NX-100S units to the network and turn on each power.
The LNK/ACT Indicator will light.
Step 2. Either press the Unit Scan Button or select [Scan] [Unit scan].
The MAC address, IP address, subnet mask, default gateway, and unit name of the NX-100 and
NX-100S connected to the LAN will be displayed.
Default values are factory-preset as follows:
IP address: 192.168.1.1
Subnet mask: 255.255.255.0
Default gateway: 0.0.0.0
Name: NX-100S or NX-100
Caution
Units can only be scanned within the effective broadcast range. (See p. 6-3.)
For the units that cannot be scanned, manually add only the units connected to the LAN with the System
Setting Tool.