WORD 90: Time required for Enhanced Security erase completion
WORD 91: Current Advanced Power Management setting
bit 15-8 Reserved
bit 7-0 Current Advanced Power Management setting set by Set Features Command.
The default value for this WORD is0080h.
WORD 92: Master Password Revision Code
the value of the Master Password Revision Code set when the Master Password was last change. Valid
values are 0001h through FFFEh. A value of 0000h or FFFFh indicates that the Master Password
Revision is not supported.
WORD 93: Hardware configuration test results
bit 15 0 (Fixed)
bit 14 1 (Fixed)
bit 13 1=device detected CBLID- above V
IH
0=device detected CBLID- below V
IL
bit12-8 Device 1 hardware reset result. Device 0 shall clear these bits to zero.
Device 1 shall set these bits as follows :
12 Reserved.
11 0=Device 1 did not assert PDIAG-.
1=Device 1 asserted PDIAG-.
10-9 These bits indicate how Device 1 determined the device number:
00=Reserved.
01=a jumper was used.
10=the CSEL signal was used.
11=some other method was used or the method is unknown.
8 1 (Fixed)
bit 7-0 Device 0 hardware reset result. Device 1 shall clear these bit to zero.
Device 0 shall set these bills as follows:
7 Reserved.
6 0=Device 0 does not respond when Device 1 is selected.
1=Device 0 responds when Device 1 is selected.
5 0=Device 0 did not detect the assertion of DASP-.
1=Device 0 detected the assertion of DASP-.
4 0=Device 0 did not detect the assertion of PDIAG-.
1=Device 0 detected the assertion of PDIAG-.
3 0=Device 0 failed diagnostics.
1=Device 0 passed diagnostics.
2-1 These bits indicate how Device 0 determined the device number:
00=Reserved.
01=a jumper was used.
10=the CSEL signa was used.
11=some other method was used or the method is unknown.
0 1 (Fixed)
WORD 94: Current automatic acoustic management value
bit 15-8 Vendor’s recommended acoustic management value
bit 7-0 Current automatic acoustic management value
This function is not supported. The value for this WORD is 0000h.
WORD 95-99: Reserved
WORD 100-103: Maximum User LBA for 48-bit Address feature set
The value for this WORD is XXXXh.
WORD 104-126: Reserved
WORD 127: Removable Media Status Notification feature set supported