Toshiba B-SX6T Series Barcode Reader User Manual


 
2. PRINTER SETUP ENGLISH VERSION EO1-33056
2.8 Setting an Operating Environment
E2-32
2.8.1 Parameter Setting
(Cont.)
(22) Input Prime Selection
This parameter is to choose whether to enable a reset operation when
INIT signal is ON.
Normally, when the printer receives a reset request signal (nInit signal)
from the host via Centronics interface, the printer will be reset and turn to
the idle state.
When the INPUT PRIME parameter is set to OFF, the printer is reset but
does not turn to idle.
When this parameter is set to ON, the host sends an INIT signal and the
printer turns to idle each time the printer is turned on. If you would like
to avoid this processing, set this parameter to OFF.
When “<2>PARAMETER SET” appears, press the [PAUSE] key until
the following display appears.
Use the [FEED] or [RESTART] key to select a desired option.
After selecting the Input Prime, press the [PAUSE] key.
(23) Expansion I/O Interface Type Selection
This parameter is to choose a type of the Expansion I/O interface
operating mode.
This parameter should be set depending on the expansion I/O control
specification of the device to be connected via the expansion I/O
interface. For details, refer to the External Equipment Interface
Specification.
When “<2>PARAMETER SET” appears, press the [PAUSE] key until
the following display appears.
Use the [FEED] or [RESTART] key to select a desired option.
After selecting an Expansion I/O Interface type, press the [PAUSE] key.
<2>PARAMETER SET
EX.I/O TYPE1
EX.I/O TYPE1
EX.I/O TYPE2
[RESTART]
[FEED]
TYPE1: Standard mode
TYPE2: Inline mode
<2>PARAMETER SET
INPUT PRIME ON
INPUT PRIME ON
INPUT PRIME OFF
[RESTART]
[FEED]
Available
Unavailable