Toshiba B-SX6T Series Barcode Reader User Manual


 
2. PRINTER SETUP ENGLISH VERSION EO1-33056
2.8 Setting an Operating Environment
E2-35
2.8.1 Parameter Setting
(Cont.)
(28) Maxi Code Specification Selection
This parameter is to choose a Maxi code specification.
When “<2>PARAMETER SET” appears, press the [PAUSE] key until
the following display appears.
Use the [FEED] or [RESTART] key to select a desired option.
After selecting a Maxi code specification, press the [PAUSE] key.
(29) Strip Motor Torque Selection
This parameter is to choose a strip motor torque.
When “<2>PARAMETER SET” appears, press the [PAUSE] key until
the following display appears.
This parameter is fixed to R0.
Press the [PAUSE] key.
(30) Stabilizer Function Selection
This parameter is to choose whether to use the stabilizer function.
The stabilizer function reduces the sound of printing.
When “<2>PARAMETER SET” appears, press the [PAUSE] key until
the following display appears.
Use the [FEED] or [RESTART] key to select a desired option.
After selecting the stabilizer function, press the [PAUSE] key.
<2>PARAMETER SET
MAXI CODE TYPE1
MAXI CODE TYPE1
MAXI CODE TYPE2
[RESTART]
[FEED]
TYPE1: Compatible specification
with the B-X series
TYPE2: Specification for specific
home delivery company
<2>PARAMETER SET
PEEL OFF TRQ R0
<2>PARAMETER SET
STABILIZER ON
STABILIZER ON
[RESTART]
[FEED]
ON: Sound of printing is
reduced.
OFF: Normal printing
STABILIZER OFF
NOTE:
The stabilizer function is available
only to the thermal direct print mode.