3.2. IN-LINE REPORTS
3.2.1. IN-LINE REPORT COMMAND EXECUTIONS
Before taking in-line reports, please note the following:
1) In-line Reset Reports (as well as In-line Read Reports) can be taken on the Master Terminal
as long as the Satellite Terminals are in the idle state (“Signed OFF” condition is not neces-
sarily required; NOTE below). To check status of all the terminals connected to the in-line
loop, TERMINAL CONDITION CHECK can be operated (refer to Chapter 2).
2) When In-line Reports are taken, the power of each Satellite terminal must be turned ON but
the Mode Lock can be in any positions.
The operation flow for taking In-line Reports is shown on the next page, and the table of In-line
Reports is on the following pages.
The key operation for each In-line Report is the same as the corresponding terminal report
available on the standalone ECR. However, the key operation can be executed only on the
Master Terminal while the [RTR] key is turned on.
Conditions required on terminals for In-line Report takings:
Read/Reset Reports (Daily or GT)
Master Terminal: Any time outside a sale
Satellite Terminals: (NOTE below)
Lock Positions Required:
Master Terminall: Mode Lock : X/RTR Declaration : ON
Mode Lock : Z/RTR Declaration : ON
Satellite Terminals: Any positions
NOTE: Conditions required on the Satellite Terminals for in-line report takings depend on
the cashier identification features.
• Cashier code entry type ............ Satellite Terminal during sign OFF, and sign
ON with no sales entries performed
• Cashier key type........................ Satellite Terminal during idling
WARNING!
When opening the cash drawer, be careful not to let the drawer hit any person.