Uniden BC296D Scanner User Manual


 
Programming Type 2/Digital 800 and 900 MHz
Systems
To program a Type 2/Digital 800 or 900 MHz system, you
need to know the frequencies that the system uses.
1. Select the trunk programming mode.
2:SCAN OPTION 2:TRUNK
2. Use the scroll bar to select the bank you want to program,
then press E.
1:TRUNK TYPE 1:ON
3. Select one of the following trunk types for Motorola Type 2
or digital Systems:
1:TYPE2/P25 800
Motorola Type 2 or Digital systems in the 800 MHz
band
3:TYPE2/P25 900
Motorola Type 2 or Digital systems in the 900 MHz
band
4. Select the channel to store the information into.
2:TRUNK CHANNEL
Use the scroll bar to select a channel within the bank to
store a system frequency, then press E.
5. Store the channel information
1:FREQUENCY
Enter the frequency for the channel, then enter an Alpha
Tag for the channel.
Repeat Steps 4 and 5 to store the rest of the frequencies for
the system. Then, see “Programming Talkgroups.”
Programming Type2/Digital VHF and UHF
Systems
To program a Type 2/Digital VHF or UHF system, you need to
know the frequencies the system uses and also the Base,
Space, and Offset settings. These settings are normally
provided along with the system frequencies.
1. Select the trunk programming mode.
2:SCAN OPTION 2:TRUNK
2. Use the scroll bar to select the bank you want to program,
then press E.
1:TRUNK TYPE 1:ON
50