Uniden BR330T Scanner User Manual


 
56
4. Using the scroll control, select a number between
-8 and 7 seen in the lower right corner of the dis-
play. Adjust the setting for the best reception.
5. When set, tap scroll once to exit.
Adjusting the Display Contrast
Settings
Adjust Contrast
Contrast 1 - 15 the scanner adjusts the display to
the contrast level you select.
This setting controls the display’s contrast (how light
or dark it appears). Use this setting to change the
contrast for different viewing conditions. There are 15
contrast settings. You see the change in contrast as
you scroll through the settings.
Initializing the Scanner’s Memory
1. Turn off the scanner.
2. Press 2, 9, and Hold while turning on the scanner.
Restore Preprogram List?
Yes="E"/ No="." appears.
3. Press ''E'' or ''.''
Connecting Your Scanner to a
Personal Computer
To connect your scanner to a personal computer, you
must first set the scanner’s baud rate (the rate at
which data is transferred between the scanner and the
computer, in bits per second (bps).
Important! Before you start trans-
ferring data between your scanner
and your computer, make sure the
batteries are fresh or fully charged.
If the scanner loses power while
you are transferring data, its
memory might be corrupted and all
information programmed in the scanner
might be erased.
Menu