Western Telematic NPS-2HD Switch User Manual


 
2. Password: (Up to 16 Characters) Assigns a User
Password to this plug. When a User Password is assigned,
the plug is then "owned" by that password. When a User
Password is entered at login, the user will have access to
only the plug(s) which are owned by this password.
(Default = undefined).
Notes:
·
If you wish to allow a single user to access both
switched plugs, assign the same User Password to
both plugs.
·
If the System Password is defined, and the plug's
User Password is not defined, then the System
Password will "own" this plug, and only the
System Mode will be able to control the plug.
3. Boot Delay: During a Boot cycle, power to the plug is
first switched off and then switched back on. The Boot
Delay is the length of time which elapses between the time
when power is switched off and the time that power is
restored. The Boot Delay can be 1, 5, 10, 15, 30 or 60
seconds. (Default determined by Option Switch 2; Factory
Setting = 5 Seconds).
4. Power-Up Default: Determines how this plug will react
when the /D (default) command is invoked, or after a
power interruption. Each plug can be automatically
switched On or Off as specified by the Power-Up Default.
(Default = On).
After Plug Parameters have been defined, press [Esc] to exit
from the Plug Parameters menu.