Zebra Technologies H 2824-Z Printer User Manual


 
50 LP 2824-Z User Guide 980531-001 A
Troubleshooting
Manual Calibration
Manual Calibration
Manual calibration is recommended whenever you are using pre-printed media or if the printer
will not correctly auto calibrate.
1. Make sure media is loaded.
2. Turn on the printer power.
3. Press and hold the feed button until the green status LED flashes once, then twice.
Release the feed button.
4. The printer will set the media sensor for the label backing being used. After it is done
making this adjustment, the roll will automatically feed until a label is positioned at the
print head.
5. A profile of the media sensor settings (similar to the example below) will print. Upon
completion, the printer will save the new settings in memory and the printer is ready for
normal operation.
6. Press the feed button. One entire blank label will feed. If this does not happen, try
defaulting (refer to the four-flash sequence in “Feed Button Modes” later in this chapter)
and recalibrating the printer.
Note • Performing a manual calibration disables the auto calibration function. To return to
auto calibration, default the printer (see the four-flash sequence in “Feed Button Modes” later
in this chapter).