A SERVICE OF

logo

Figure 6-15 Install the FCO serial communications bridge cable (bottom view of the FCO)
13. Prepare to insert the appropriate SFP (Small Form Factor Pluggable) trans-
ceiver into the FCO. Note that the SFP adapter is keyed and the small circuit
board connector is facing you when oriented correctly. See Figure 6-16. Locate
the rectangular opening in the bottom of the Fibre Channel Option and insert
the SFP transceiver connector end first. Then carefully guide the SFP trans-
ceiver into the FCO until it clicks into place. Refer to Figure 6-17.
Small circuit board is facing you
when oriented correctly for insertion.
Figure 6-16 End View of Small Form Factor Pluggable Transceiver
Rectangular opening in bottom
of Fibre Channel Option.
SFP adapter fully inserted
into Fibre Channel Option.
Figure 6-17 Inserting SFP Adapter into Fibre Channel Option
6.6 Initializing the Fibre Channel Option
After physically installing the Fibre Channel Option onto the library, disconnect (if
connected) the Fibre Channel Option from the FC host or Hub to avoid affecting any
operational systems.
NOTE
Refer to the applicable TLS Installation and Operation manual for instructions on using the TLS
Library and its menus.
501440 Rev. G FCO Type C Installation 6-17