Acer 800 Laptop User Manual


 
70 Chapter 4
Index of Error Messages
Error Message List
Error Messages FRU/Action in Sequence
0200 Failure Fixed Disk Hard disk error detected.
Check to see if fixed disk is attached properly.
Enter the BIOS Setup Utility and verify the hard disk is detected.
0211 Keyboard error see “Keyboard or Auxiliary Input Device Check” on page 65.
0212 Keyboard Controller Failed see “Keyboard or Auxiliary Input Device Check” on page 65.
May require replacing the keyboard controller.
0213Keyboard locked - Unlock key switch Unlock the system to proceed.
0220 Monitor type does not match CMOS - Run
SETUP
Display device mismatch.
Enter the BIOS Setup Utility and verify the parameters (try loading
the default settings); then save and restart the computer.
0230 System RAM Failed at offset: nnnn Shadow RAM test failed
Main board
0231 Shadow RAM Failed at offset: nnnn System RAM test failed
Main board
0232 Extended RAM Failed at address line: nnnn Extended RAM test failed
Main board
0250 System battery is dead - Replace and run
SETUP
CMOS clock battery needs to be replaced. Replace the battery and
run BIOS Setup Utility to reconfigure system time, then reboot
system.
0251 System CMOS checksum bad - Default
configuration used
CMOS has been corrupted or modified incorrectly.
Run BIOS Setup Utility and verify the parameters; then save and
restart the computer.
Check the system battery.
0260 System timer error System timer test fiailed, and the main board needs to be repaired.
Run BIOS Setup Utility to reconfigure system time, then reboot
system.
Main board
0270 Real time clock error RTC battery
Run BIOS Setup Utility to reconfigure system time, then reboot
system.
Main board
0280 Previous boot incomplete - Default
configuration used
Previous boot-up was not copleted successfully.
Enter the BIOS Setup Utility and verify the parameters (try loading
the default settings); then save and restart the computer.
RTC battery
Main board
0281 Memory size found by POST differed from
EISA CMOS
Run “Load Setup Defaults” in BIOS Setup Utility.
Main board
02B0 Diskette drive A error Drive A: or B: is present but fails the BIOS POST diskette tests.
Check the drive is defined with the proper diskette type in BIOS
Setup Utility
Check if the diskette drive is attached correctly.
See “External Diskette Drive Check” on page 64.
02B2 Incorrect Drive A type - run SETUP Type of floppy drive A: not correctly identified in Setup.
Main board
02D0 System cache error - Cache disabled RAM cache failed and BIOS disabled the cache.
On older boards, check the cache jummpers. You may have to
replace the cache.
Main board
SG_TM800.book Page 70 Thursday, February 27, 2003 10:21 PM