Acer G300 Series Server User Manual


 
5 Configuring IDE Software RAID
106
Physical Drive Error Status - This screen displays the physical drive
error status. This table provides a description of each field.
Physical Drive Errors - Error codes for the physical drives display
when you select the error log view. The following table provides a list
and descriptions of the error codes.
Array
To display the Array Properties, perform a Check Consistency, or rebuild
the array, click the icon in the lower middle frame next to Array.
After you click the icon, the Array ID displays in the right frame. The
links to the Array Properties, Check Consistency, and Rebuild display as
Capacity Specifies the capacity of this physical drive.
Transfer Mode Specifies the type of transfer mode used on this physical drive.
Part of Array Specifies the part of the array wo which this physical drive belongs.
The RAID mode for a striped array (RAID 0) is called performance,
and for a mirrored array (RAID 1) is called reliability.
Connection Specifies the type of IDE connection that is used to connect this drive
to the RAID controller. (primary or secondary, master or slave)
Model Specifies the model number of the physical drive.
Serial Number Specifies the serial number of the physical drive.
Field Description
Time and Date Specifies the time and date the error was logged.
Error Specifies the error type.
Sector Specifies the sector that contains the error.
Code Description
Error 01 Media read error. The disk surface is damaged.
Error 02 Media write error. The disk surface is damaged.
Error 03 Media verify error.
Error 04 Missing drive type.
aa300.book Page 106 Tuesday, December 17, 2002 5:27 PM