1 System overview
8
Weight
The table below lists the weight of individual components used in
deployment of this system in third-party racks.
Power consumption
The server power supply is rated for a maximum 220W DC output.
Maximum input AC power consumption is approximately _____.
• Using 110V AC power, a fully loaded system can consume up to
2.80A
• Using 220V AC power, a fully loaded system can consume up to
1.40A
Deployment of ultra-dense 1U servers represent a significant power
requirement. A simple formula to calculate server power requirements
for an installation is:
(Number of servers) x (307W) = maximum power requirements for servers
Item Weight in Kg Weight in lbs
Fully configured
system
13 Kg 28.6 lbs
Rack mount kit 3.1 Kg 6.82 lbs
CPU and fan sink 0.35 Kg 0.77 lbs
Hard disk drive 1Kg 2.2 lbs
Power supply module 1.3 Kg 2.86 lbs
Floppy disk drive 0.16 Kg 0.35 lbs
CD-ROM drive 0.3 Kg 0.66 lbs
PCI card 0.04 ~ 0.4 Kg 0.09 ~ 0.88 lbs
aa r500.book Page 8 Thursday, September 20, 2001 11:06 AM