Acer Series 520 Network Card User Manual


 
7-4 Troubleshooting
Copyright © 2002 by LSI Logic Corporation. All rights reserved.
7.3 Other BIOS Error Messages
Table 7.3 describes other BIOS error messages, their meaning, and
suggested solutions.
1 Logical Drive
Degraded
A logical drive signed on
in a degraded state.
Make sure all physical drives are properly
connected and are powered on.
Run MegaRAID Manager to find out if any
physical drives are not responding. Reconnect,
replace, or rebuild any drive that is not
responding.
The following SCSI IDs
are not responding:
Channel x:a.b.c
The physical drives with
SCSI IDs a, b, and c are
not responding on SCSI
channel x.
Make sure the physical drives are properly
connected and are powered on.
Table 7.2 BIOS Boot Error Messages (Cont.)
Message Problem Suggested Solution
Table 7.3 Other BIOS Error Messages
Message Problem Suggested Solution
Following SCSI disk
not found and no
empty slot available
for mapping it
The physical disk roaming
feature did not find the
physical disk with the
displayed SCSI ID. No slot is
available to map the physical
drive. MegaRAID cannot
resolve the physical drives
into the current configuration.
Reconfigure the array.
Following SCSI IDs
have the same data y,
z
Channel x: a, b, c
The physical drive roaming
feature found the same data
on two or more physical drive
on channel x with SCSI IDs a,
b, and c. MegaRAID cannot
determine the drive that has
the duplicate information.
Remove the drive or drives that should not
be used.