Installing and Removing an LS Module
79
Installing and Removing an LS Module
The LS Modules are located in the front of the enclosure.
Follow these procedures to install and remove the LS
Modules.
Installing an LS
Module
1 Select the LS Module slot in to which the LS Module is to be
inserted and remove the LS blank if one is installed.
2 Orient the LS Module such that the LEDs are on the top (on the
right for deskside systems).
3 With the cam lever fully open slide the LS Module into the slot
until the lever starts to close.
4 Fully close the cam lever. The lever is fully closed, and the LS
Module locked in place, when the lever “clicks” into position.
Removing an LS
Module
1 Using your finger, release the locking tab by pressing it in the
direction shown in Figure 5-2, and pull the cam lever towards
you.
2 Fully open the cam lever (approx. 90
o
to enclosure).
3 Gently, pull the LS Module out of the enclosure.
CAUTION: Immediately replace the LS Module or install an LS
Module blank to maintain correct airflow.