Adaptec MAN-FC2002-001 Computer Drive User Manual


 
Installing and Removing an I/O Module/RAID Controller
83
Installing and Removing an I/O Module/RAID Controller
Note: In the following section, “I/O Module” is taken to
include the RAID Controller in addition to the I/O Module.
The I/O module is located in the rear of the enclosure.
Follow these procedures to install and remove the I/O
module.
Installing an I/O
Module/RAID
Controller
1 Remove the I/O module blank if there is one installed.
2 Gently insert the I/O module into the slot.
3 Secure in place using the two fixing screws (torque setting
0.3Nm).
4 Connect the cables as described in Chapter 3.
Removing an I/O
Module/RAID
Controller
1 Remove all cables.
2 Loosen the two fixing screws.
3 Using the module handle, gently slide the I/O Module out of the
slot.
CAUTION: Immediately replace the carrier or install an I/O mod-
ule blank to maintain correct airflow.