ADTRAN 3060 Network Card User Manual


 
10 Section 61182007L1-5, Issue 1 61182007L1-5A
The Provisioning Screen, as illustrated in Figure 11,
displays current provisioning settings and allows for
changing the system configuration. Provisioning
changes are only allowed at the CO end of the circuit.
The unit retains the last provisioning changes to
determine its operating mode.
Figure 12. Network Source Screen
Figure 11. Provisioning Screen
Shelf: 1 Slot: 5 Total Access System 04/07/01 09:06
Unacknowledged Alarms: MAJOR MINOR
Circuit ID:
Provisioning
1. Framing CAS
2. CRC4 Enabled
3. Coding HDB3
4. G.703 Clock Internal
5. Loopback Timeout None
6. Service State In Service
7. Network Source G.703
8. G.703 External Alarms Disabled
9. Core Frame Mapping Method 1
Selection:
‘?’ - System Help Screen
Shelf: 1 Slot: 5 Total Access System 04/07/01 09:27
Unacknowledged Alarms: MAJOR MINOR
Circuit ID:
Network Source
1. G.703
2. MUX A
3. MUX B
Selection:
‘?’ - System Help Screen
The Network Source Screen, illustrated in Figure 12,
allows the user to provision the unit to receive its
network signal from either MUX or a G.703 source.