ADTRAN 3060 Network Card User Manual


 
11Section 61182007L1-5, Issue 161182007L1-5A
The Status Screen, illustrated in Figure 13, provides
quick access to status information for both the LTU
and NTU, in addition to any regenerators.
Type “3” to view the status screen for REG #1, as
illustrated in Figure 14. If the circuit involves a
second REG, press “4” from the REG #1 Status
Screen to view the REG#2 Status Screen.
Figure 13 and Figure 14 consolidate current
information for the HDSL and E1 interfaces. A key to
the information provided is found in the center of the
screen. Arrows indicate the key statistics, which
apply to both the remote and customer site
components.
Indications of Loopback and Sealing Current (if
present) are given at the bottom of the first key
column. Status and configuration information for the
LTU and NTU E1 signals are located in the center of
the Status Screen near the bottom.
Figure 14. REG #1 Status Screen
Shelf: 1 Slot: 5 Total Access System 04/07/01 09:14
Unacknowledged Alarms: MAJOR MINOR
Circuit ID:
Loop 1 <Network> Loop 2 Loop 1 <Customer> Loop 2
00 dB 00 dB <- Loss -> 00 dB 00 dB
Yes Yes <- Sync -> Yes Yes
000/00000 000/00000 <-ES 15M/24H -> 000/00000 000/00000
000/00000 000/00000 <-SES 15M/24H -> 000/00000 000/00000
000/00000 000/00000 <-UAS 15M/24H -> 000/00000 000/00000
Loopback Inactive Sealing Current Present Loopback Inactive
[X] 9 [X] [X] 9 [X]
[X] 8 [X] [X] 8 [X]
[X] 7 [X] ____ LP1 ____ LP1 ____ ____ [X] 7 [X]
[X] 6 [X] |LTU | |REG1| |REG2| |NTU | [X] 6 [X]
[X] 5 [X] | |===N| |C===| |====| | [X] 5 [X]
[X] 4 [X] | | | | | | | | [X] 4 [X]
[X] 3 [X] | |===N| |C===| |====| | [X] 3 [X]
[X] 2 [X] |____| |____| |____| |____| [X] 2 [X]
[X] 1 [X] LP2 LP2 [X] 1 [X]
[X] 0 [X] [X] 0 [X]
1. Zero Registers Selection: 3. REG1 Status
2. LTU/NTU Status ‘?’ - System Help Screen 4. REG2 Status
Figure 13. Status Screen
Shelf: 1 Slot: 5 Total Access System 04/07/01 09:15
Unacknowledged Alarms: MAJOR MINOR
Circuit ID:
LTU LTU/NTU Status NTU
Loop 1 <Network> Loop 2 Loop 1 <Customer> Loop 2
01 dB 01 dB <- Loss -> 01 dB 01 dB
Yes Yes <- Sync -> Yes Yes
000/00000 000/00000 <-ES 15M/24H -> 000/00000 000/00000
000/00000 000/00000 <-SES 15M/24H -> 000/00000 000/00000
000/00000 000/00000 <-UAS 15M/24H -> 000/00000 000/00000
Loopbacks Inactive Sealing Current Present Loopbacks Inactive
LTU Signal Quality LTU E1 NTU E1 NTU Signal Quality
[X] 9 [X] [X] 9 [X]
[X] 8 [X] CAS <- Frame -> CAS [X] 8 [X]
[X] 7 [X] HDB3 <- Code -> HDB3 [X] 7 [X]
[X] 6 [X] ENABLED <- CRC4 -> ENABLED [X] 6 [X]
[X] 5 [X] METH1 <- CFM -> METH1 [X] 5 [X]
[X] 4 [X] 00000 <- BPV -> 00000 [X] 4 [X]
[X] 3 [X] 00000 <- ES -> 00000 [X] 3 [X]
[X] 2 [X] 00000 <- SES -> 00000 [X] 2 [X]
[X] 1 [X] 00000 <- UAS -> 00000 [X] 1 [X]
[X] 0 [X] None <- Alarms -> None [X] 0 [X]
1. Zero Registers Selection: 3. REG1 Status
2. LTU/NTU Status ‘?’ - System Help Screen 4. REG2 Status