ADTRAN 3060 Network Card User Manual


 
13Section 61182007L1-5, Issue 161182007L1-5A
At each 15-minute interval, the performance
information is transferred to the 15-minute
performance data register accessed from the
Performance History screen. At each 24-hour
interval, the performance data is transferred into the
24-hour performance data register also accessed using
the Performance History screen. The Performance
History screen is shown in Figure 17.
Figure 17. Performance History Screen
Shelf: 1 Slot: 5 Total Access System 04/07/01 09:17
Unacknowledged Alarms: MAJOR MINOR
Circuit ID:
LTU G.703 Performance Data
15 Minute History
Current Error Regs ES SES UAS BPV
Menu ES SES UAS BPV 09:15 000 000 000 000
1. LTU G.703 15 Min: 000 000 000 000 09:00 --- --- --- ---
2. LTU Loop 1 24 Hr: 00000 00000 00000 00000 08:45 --- --- --- ---
3. LTU Loop 2 08:30 --- --- --- ---
4. NTU G.703 08:15 --- --- --- ---
5. NTU Loop 1 24 Hour History 08:00 --- --- --- ---
6. NTU Loop 2 ES SES UAS BPV 07:45 --- --- --- ---
7. REG1 NET Lp1 09/21 ----- ----- ----- ----- 07:30 --- --- --- ---
8. REG1 NET Lp2 09/20 ----- ----- ----- ----- 07:15 --- --- --- ---
9. REG1 CST Lp1 09/19 ----- ----- ----- ----- 07:00 --- --- --- ---
10. REG1 CST Lp2 09/18 ----- ----- ----- ----- 06:45 --- --- --- ---
11. REG2 NET Lp1 09/17 ----- ----- ----- ----- 06:30 --- --- --- ---
12. REG2 NET Lp2 09/16 ----- ----- ----- ----- 06:15 --- --- --- ---
13. REG2 CST Lp1 09/15 ----- ----- ----- ----- 06:00 --- --- --- ---
14. REG2 CST Lp2 05:45 --- --- --- ---
05:30 --- --- --- ---
B. Page back Selection: Page 1
F. Page forward ‘?’ - System Help Screen most recent data
Type the corresponding number to view the
Performance History data for customer or network
loops.
From the Status Screen, type “1” to reset the current
performance registers to zero on the Status and
Performance History Screens.
Figure 16. Test Screen
Shelf: 1 Slot: 5 Total Access System 04/07/01 09:16
Unacknowledged Alarms: MAJOR MINOR
Circuit ID:
Test
1. Selftest
2. Loopback to Network at LTU = Inactive
3. Loopback to Customer at LTU = Inactive
4. Loopback to Network at NTU = Inactive
5. Loopback to Customer at NTU = Inactive
6. Loopback to Network at REG-1 = Inactive
7. Loopback to Network at REG-2 = Inactive
_____ _____ _____ _____
| LTU | LP1 |REG 1| LP1 |REG 2| LP1 | NTU |
--->|-----|<=====>|-----|<=====>|-----|<=====>|-----|<—-
| | | | | | | |
NET | | | | | | | | CUST
| | LP2 | | LP2 | | LP2 | |
<---|-----|<=====>|-----|<=====>|-----|<=====>|-----|—>
|_____| |_____| |_____| |_____|
Selection:
‘?’ - System Help Screen