ADTRAN 5045 Network Card User Manual


 
Section 3 Engineering Guidelines TRACER 5045 System Manual
28 © 2003 ADTRAN, Inc. 612805045L1-1A
RS-232 Connection (DB-25) — Terminal Use
The RS-232 connector provides a female DB-25 terminal connection (wired as a DCE interface), which is
used for terminal access to the TRACER 5045 system. The
RS-232 port provides the following functions:
Accepts EIA-232 input from a PC or terminal for controlling the TRACER 5045 system
Operates at 9600 bps
Table 2 on page 28 shows the pinout. Wiring diagrams for connecting to the RS-232 connector (for various
applications) are provided following the pinout.
Table 1. Rear Panel Description
1
1 Detailed discussions (including pinouts) of rear panel components (where applicable) follow the table.
Name Connector Description
A
RS-232 DB-25 (female)
VT100 terminal (or PC with terminal emulation software)
connection
B Test 1/4” bantam Factory test connection
C 10/100BaseT/TX RJ-48C 10/100BaseT/TX Ethernet interfaces for LAN connections.
D Alarm Terminal block External alarm monitoring system connection
E DC Power Terminal block 21-60 VDC power source connection
F Fuse N/A 2 A, 250 V, 2 inch slow-blo fuse
G Antenna N-Type Antenna feedline cable connection
H Ground Lug N/A Earth ground connection
Table 2. RS-232 Connection Pinout
PIN NAME DESCRIPTION
1, 7
GND Ground
2 TX Transmit
3 RX Receive
4 RTS Request To Send
5 CTS Clear To Send
6 DSR Data Set Ready (Modem Control Only)
8 CD Carrier Detect
9-19 Unused
20 DTR Data Terminal Ready (Modem Control Only)
21 Unused
22 RI Ring Indicator
23-25 Unused