ADTRAN T3SU 300 Network Card User Manual


 
Chapter 3. Configuration
3-16 T3SU 300 User Manual 61200217L1-1
Table 3-1. Near End Alarm Trap Descriptions
Table 3-2. Far End Alarm Trap Descriptions
Trap Type If ENABLED, this trap is sent...
Red Alarm
(LOS)
when the unit detects a loss of signal.
Out of Frame
(OOF)
when the unit detects an out of frame condition.
Yellow Alarm
(RAI)
when the unit detects an incoming RAI signal.
Blue Alarm
(AIS)
when the unit detects an incoming AIS signal.
Idle Signal when the unit detects an incoming idle signal
(1100) over the entire DS3 bandwidth.
Trap Type If ENABLED, this trap is sent...
Red Alarm
(LOS)
when the unit receives indication from the far
end unit through the FEAC channel that the far
end unit has lost its receive signal.
Out of Frame
(OOF)
when the unit receives indication from the far
end unit through the FEAC channel that the far
end unit has lost frame synchronization with the
network.
Yellow Alarm
(RAI)
when the unit receives indication from the far
end unit through the FEAC channel that the far
end unit is receiving an RAI indication from the
network.
Blue Alarm
(AIS)
when the unit receives indication from the far
end unit through the FEAC channel that the far
end unit is receiving an AIS indication from the
network.