Airlink Raven and PinPoint CDMA Network Card User Manual


 
Raven and PinPoint CDMA User Guide Version 1.12
AirLink Communications, Inc. Page 66 March 24, 2004
13 PinPoint CDMA Technical Specifications
13.1 Physical Characteristics:
Weight: < 2 lb.
Size: 3.3” wide x 2” high x 6.8" long
RF Antenna Connector: 50 Ohm TNC
Serial Interface: RS232 DB-9F
13.2 Power Specifications:
Advanced Power Management features
Input Voltage: 10 VDC to 28 VDC
Input Current: 20 mA to 600 mA
Typical Transmit/Receive: 300ma at 12VDC
Dormant connection [idle for 10-20 seconds] 150 ma at 12 VDC
Low power mode: 20 mA at 12 VDC
13.3 Environmental:
Operating ranges: -30°C to +75°C*
(<10%duty cycle limit above 60 °C)
Humidity: 5%-95%Non-condensing
A thermistor inside the modem (monitored by the modem CPU firmware) causes flow
control to be activated should the internal temperature reach 75ºC (167ºF) as
measured at the radio. Flow control is released when the temperature falls below 75.
Should the temperature of the radio reach 80ºC (176ºF), the modem terminates the
connection in order to protect components and avoid drifting outside radio
specifications.