OmniSwitch 6600 Series Chassis and Hardware Components Viewing Basic Chassis Information
OmniSwitch 6600 Series Hardware Users Guide April 2004 page 2-53
Viewing Basic Chassis Information
This section covers the following basic chassis information and monitoring commands:
Important Hardware Status Commands. Additional commands, used to view important hardware status
information, are described earlier in this chapter:
• For information on viewing primary and back up power supply status, refer to page 2-23.
• For information on viewing chassis temperature status, refer to page 2-42.
• For information on viewing chassis fan status, refer to page 2-45.
Hardware Information
To view basic hardware information about the switch, enter the show hardware info command at the CLI
prompt. This command displays the following information:
• CPU type
• Flash and RAM memory information
• NVRAM battery status
• Jumper settings
• BootROM and Miniboot versions
For example:
-> show hardware info
CPU Type : PowerPC 8245,
Flash Manufacturer : SanDisk SDCFB-32
Flash size : 32505856 bytes (31 MB),
RAM Manufacturer : DataRam,
RAM size : 134217728 bytes (128 MB),
NVRAM Battery OK : YES,
Interrupt Boot Jumper : ON,
Force UART Defaults Jumper : ON,
Run Extended Memory Diags Jumper : ON,
Spare Jumper : ON,
BootROM Version : 5.1.2.125,
Backup Miniboot Version : 5.1.2.125,
Default Miniboot Version : 5.1.2.125,
Stacked Configurations. For remote sessions (e.g., Telnet and WebView) the show hardware info
command displays information for only the primary switch. The command may also be used while
connected directly to the primary or secondary switch via the console port. For detailed information on
stacked OS6600 series switches, refer to Chapter 3, “Managing OmniSwitch 6600 Series Stacks.”
show hardware info
show module
show module long (and show ni)
show chassis
show cmm