Altinex MT107-103 Switch User Manual


 
MULTITASKER
400-0367-005 9
2. [C]
This command displays the active matrix
configuration, input-to-output connections, and
output on/off status.
Command Format: [Cn]
Cn = Card ID (n = slot # from 1 to max slots)
Example:
There is an MT107-103 in slot 8. Send [C8] and
the card will return feedback in the following
format:
Matrix mode:non-blocking
Matrix number:1
Matrix size:64X64
Input offset:0
Output offset:0
Channel width:1
Channel space:0
OUT
1-8 : 1 1 1 1 1x 1x 1x 1x
9-16 : 9x 10x 11x 12x 13x 14x 15x 16x
17-24 : 17x 18x 19x 20x 21x 22x 23x 24x
25-32 : 25x 26x 27x 28x 29x 30x 31x 32x
33-40 : 33x 34x 35x 36x 37x 38x 39x 40x
41-48 : 41x 42x 43x 44x 45x 46x 47x 48x
49-56 : 49x 50x 51x 52x 53x 54x 55x 56x
57-64 : 57x 58x 59x 60x 61x 62x 63x 64x
Description of Feedback:
The first line of the status shows the matrix in
non-blocking mode (see [MODE] command for
details). The next line lists the matrix number
followed by 5 lines that describe the properties
of the matrix. The second half of the status, the
remaining 8 lines, shows the input-to-output
connections and the output on/off status.
In the above example, Matrix 1 is the active
matrix and is configured as a 64X64 matrix with
no input or output offset. The channel width is 1,
and the channel spacing is 0, so each of the 64
inputs and outputs are switched individually.
The last 8 lines of the status are the connection
settings, and each output on/off status. The top
line shows the inputs that are connected to
Outputs 1-8 and the next line shows the inputs
that are connected to Outputs 9-16, and so on.
The lowercase “x” next to the input number
indicates that its output is turned off. In this
case, Input 1 is connected to Outputs 1-8,
Output 9 is connected to Input 9, Output 10 to
Input 10, and so on. Outputs 5-64 are turned
off.
3. [CnS]
This command saves the input-to-output
connections and on/off settings. This
configuration will be restored after the system is
reset or powered off, then back on.
Command Format: [CnS]
Cn = Card ID (n = # from 1 to max slots)
S = save configuration
Example:
Save the setup from the example in the previous
command by sending [C8S]. The feedback
would be as follows:
VIS:OFF
Matrix mode:non-blocking
Matrix number:1
Matrix size:64X64
Input offset:0
Output offset:0
Channel width:1
Channel space:0
OUT
1-8 : 1 1 1 1 1x 1x 1x 1x
9-16 : 9x 10x 11x 12x 13x 14x 15x 16x
17-24 : 17x 18x 19x 20x 21x 22x 23x 24x
25-32 : 25x 26x 27x 28x 29x 30x 31x 32x
33-40 : 33x 34x 35x 36x 37x 38x 39x 40x
41-48 : 41x 42x 43x 44x 45x 46x 47x 48x
49-56 : 49x 50x 51x 52x 53x 54x 55x 56x
57-64 : 57x 58x 59x 60x 61x 62x 63x 64x
[SAVED]